Other Accessories

multi__ballast__transformer

MULTI BALLAST TRANSFORMER

Only one device for TRASY2 and COMPACT series and also for the different CT-currents. Apart from 1A, 1,5A and 5A there are now also 3A and 4A transformable.

Designs

  • With housing (IP55, also for outdoor applications)
  • Without housing, with mounting plate for cabinet mounting
  • Without housing, with mounting plate and fixing clamp for rail mounting according to EN60715
  • Delivery with M25x1,5mm Hugro-Wadi cable gland

POWER SUPPLY PSLC 242

the power supply units of the series PSLC242 are ready for installation on delivery.

FEATURES

  • The units are constructed for 230V ~ as well as for 115V~ input voltage.
  • The units are constructed for sinus-oidal input voltage.
    Output separated according to VDE 0551.
  • Suitable for the tropics – Epoxy resin cast.
  • The units are short circuit
    proofed at the output.
  • The power supplies are suitable to fitted on 35mm DIN – rail as well to be screwed on any mounting-surface.

DIGITAL DISPLAY D1270 / D1272

The digital display types D1270 and D1272 are used in the digital remote display of the oil and/or winding temperatures, and are connected with the analog output (Pt100 or 4..20mA) of the combi well or the ZT-F2.1.

The optional selection of two freely adjustable limit value contacts and of various different output signals (4..20mA, 0..5V, 0..10V) for further signal processing is available as well.

COMBI WELL

Like the thermo well, the combi well is a mounting well for the oil thermometer. It can be mounted in the DIN 42554 thermometer pocket. Additionally it features an integral Pt100 measuring resistor to DIN 43760 for transmission of the temperature measured value over a distance. The combi well consists of the immersion tube and the terminal head. The head contains the terminals for remote devices (such as a digital display) and a cable gland through to the immersion tube, for the temperature sensor of the pointer-type thermometer. Optional output signals: Cu10 as per ANSI ASME PTC 19.3 / Type: Combi well Cu10 4..20mA / Type: Combi-TT

SIGNAL CONDITIONER PT-MU

A Pt100 signal is processed by the Pt-MU signal conditioner to produce a standardized signal proportional to the temperature.

The signal conditioner may be connected to the Pt100 terminals in the ZT-F2.1 transformer temperature transmitter or in the combi well. It conditions the output signals from these devices for processing in the computer, or the electrical or electronic display.

The Pt-MU is always used when measured values have to be transmitted over a distance or if there is interference on the transmission line

Signal Converter TT30

With signal converter TT30 the most varying sensor signals can be converted into process signals. On the input side, it can adapt mechanically and electrically to the most varying sensors.
Combining mechanical base devices with the TT30 signal converter ensures maximum transformer safety and functionality. While safety-related mechanical switching functions are maintained, it is possible to simultaneously connect control room systems to process monitoring systems using current bus technologies., the most varying sensor signals can be converted into process signals. On the input side, it can adapt mechanically and electrically to the most varying sensors.

Combining mechanical base devices with the TT30 signal converter ensures maximum transformer safety and functionality. While safety-related mechanical switching functions are maintained, it is possible to simultaneously connect control room systems to process monitoring systems using current bus technologies.

TEMP TRANSMITTER ZT F2.1

The ZT-F2 transformer temperature transmitter can only be used in conjunction with a TRASY2 series dial thermometer. It is used to represent the thermal image (= winding temperature) in the transformer. The winding temperature is measured indirectly. The temperature gradient between the winding and the coolant is dependent on the current in the winding: the measuring transformer’s secondary current is proportional to the current in the winding of the transformer. The measuring transformer’s secondary current supplies a heating resistor in
the ZT-F2 transformer temperature transmitter and thus causes the display indicating the actually measured oil temperature to rise (= temperature gradient) in accordance with the load on the transformer

MEASURING TRANSDUCER Pt-MU

A Pt100 signal is processed by the Pt-MU signal conditioner to produce a standardised signal proportional to the temperature.

The signal conditioner may be connected to the Pt100 terminals in the ZT-F2.1 transformer temperature transmitter or in the combi well. It conditions the output signals from these devices for processing in the computer, or the electrical or electronic display.

The Pt-MU is always used when measured values have to be transmitted over a distance or if there is interference on the transmission line.

Product Data Sheet